Reference
Spray Foam Glossary
Quick definitions for the terms used in our rankings and product research, with a deeper guide when the buying or installation decision needs more context.
No matching term. Try an abbreviation, a broader word, or clear the search.
- Air barrier Building science
-
An air barrier limits uncontrolled airflow through the building enclosure. Its continuity at seams, transitions, and penetrations matters as much as the material used.
See how air and vapor control differ Spray Foam Guides - Air sealing Building science
-
Air sealing closes leaks at joints, penetrations, and transitions to reduce uncontrolled airflow. R-value alone does not describe this function.
Plan a continuous air-control layer Spray Foam Guides - Application temperature Materials and application
-
Application temperature covers the product, air, and substrate conditions allowed during use. The exact ranges on the label and technical documentation govern expansion, adhesion, cure, and yield.
Check whether today’s conditions fit the job - Authority having jurisdiction (AHJ) Safety and code
-
Also: AHJ, code official
The authority having jurisdiction, often shortened to AHJ, interprets and enforces applicable code and permit requirements. A listing claim does not replace its decision.
See how we treat fire and code claims - Board foot Performance and quantity
-
Also: board feet, bd ft
One board foot is a volume of 12 inches by 12 inches by 1 inch. It estimates material volume, not R-value or guaranteed field coverage.
Calculate board feet and compare coverage - Class A Safety and code
-
Class A usually describes a result within a specified surface-burning test and tested configuration. It does not by itself permit exposed foam or approve every assembly.
Read fire claims on the correct basis - Closed-cell foam Materials and application
-
Also: closed-cell spray foam
Closed-cell foam is a denser, more rigid foam category with mostly closed cells. R-value, vapor behavior, approved uses, and required thickness remain exact-product questions.
Compare open-cell and closed-cell products - Cure Materials and application
-
Also: curing
Cure is the process by which applied foam develops its intended properties. Time, temperature, moisture, mixing, and thickness can affect it, so the exact instructions govern.
Recognize foam that may not have cured correctly Spray Foam Guides - Expansion rate Performance and quantity
-
Expansion rate describes how much foam grows after dispensing. High expansion can help fill an approved joint or narrow opening but does not automatically mean higher R-value, better control, or suitability for a whole surface.
Choose a sealant by the job it must do - Fireblocking Safety and code
-
Fireblocking limits concealed draft openings in locations prescribed by code. “Fire block” foam is not automatically a rated firestop or suitable for every assembly.
Separate fire block, firestop, and fire rating - Firestop Safety and code
-
Also: firestopping
A firestop is a tested system of components around a penetration or joint in a rated wall or floor. Product color or generic “fire rated” wording does not establish a listed system.
Understand why firestop is a system - Foam sealant Materials and application
-
A foam sealant fills or seals joints, cracks, and penetrations. It should not be treated as a whole-wall insulation kit merely because it expands.
Choose a foam sealant by application - Gap filler Materials and application
-
Also: gaps and cracks foam
A gap filler is expanding foam dispensed as a bead into cracks, joints, and narrow openings. Expansion is not proof of surface insulation performance.
See why insulation foam is not gap filler - Ignition barrier Safety and code
-
An ignition barrier is a code-defined protective layer used in certain limited-access spaces and conditions. It is not interchangeable with a thermal barrier for occupied areas.
Compare ignition and thermal barriers - Isocyanates Safety and code
-
Isocyanates are reactive chemicals used to make polyurethane products, including spray foam. Spraying can create inhalation, skin, and eye exposure that requires product-specific controls.
Understand the chemical-exposure boundary Spray Foam Guides - Lift Materials and application
-
Also: foam lift
A lift is a layer or pass of foam applied to a specified thickness. Maximum thickness and time between lifts are exact-product limits that affect heat, cure, and quality.
See how application process changes by system Spray Foam Guides - Off-ratio foam Materials and application
-
Also: off ratio
Off-ratio foam results when a two-component system does not deliver its chemicals in the intended proportion. Soft, sticky, brittle, discolored, or persistently odorous material is a stop signal.
Respond safely to soft or sticky foam Spray Foam Guides - One-component foam Materials and application
-
Also: 1K foam, single-component foam
One-component foam is supplied ready to dispense and typically cures using moisture in the air or substrate. Gap sealants and open-surface products can share this chemistry but are not interchangeable.
Compare one-component and two-component formats - Open-cell foam Materials and application
-
Also: open-cell spray foam
Open-cell foam is a lower-density, softer foam category with interconnected cells. Its thermal, air-control, vapor, and water behavior must be confirmed for the exact product and assembly.
Compare open-cell and closed-cell products - Overspray Materials and application
-
Overspray is material that lands outside the intended application area. It reduces usable coverage and can damage nearby finishes, vehicles, equipment, or property if containment is poor.
Plan containment and safety before spraying - Personal protective equipment (PPE) Safety and code
-
Also: PPE
Personal protective equipment, or PPE, can include respiratory, eye, face, skin, and body protection selected for the exact task. It supplements isolation and ventilation.
Place PPE within a complete exposure-control plan Spray Foam Guides - R-value Performance and quantity
-
Also: thermal resistance
R-value measures resistance to heat flow under stated test conditions. Product claims must be compared at the same thickness, and the number does not describe whole-assembly performance by itself.
See how we compare spray foam R-value claims - Re-entry Safety and code
-
Also: re-entry period
Re-entry means returning to a work area under specified conditions and may refer to trained, protected workers. It is not automatically the same as occupant re-occupancy.
Plan ventilation and product-specific re-entry Spray Foam Guides - Re-occupancy Safety and code
-
Re-occupancy is the point when residents, children, pets, or other unprotected occupants may use the space again. It can require a different threshold from worker re-entry.
Separate re-entry from re-occupancy Spray Foam Guides - Safety Data Sheet (SDS) Safety and code
-
Also: SDS
A Safety Data Sheet, or SDS, describes product hazards, handling, protective measures, and emergency information. Use the document for the exact product and formulation.
Use the SDS within an exposure-control plan Spray Foam Guides - Spray polyurethane foam (SPF) Materials and application
-
Also: SPF, spray foam
Spray polyurethane foam, or SPF, is a broad family of polyurethane products created or applied as a spray. Small sealants, portable kits, and professional systems differ in controls and approved use.
Learn what spray foam insulation includes Spray Foam Guides - Substrate Materials and application
-
The substrate is the surface receiving the foam, such as wood, masonry, metal, or a membrane. Cleanliness, dryness, temperature, compatibility, and condition affect adhesion and cure.
Check substrate and application conditions Spray Foam Guides - Surface-spray insulation kit Materials and application
-
Surface-spray insulation kit is our category for gun-applied products positioned to cover open walls, ceilings, or similar surfaces at controlled thickness. It is an editorial category, not a universal industry certification.
Compare the current surface-spray research set - Thermal barrier Safety and code
-
A thermal barrier is a protective material or system intended to delay temperature rise of foam under specified conditions. Acceptance depends on the foam, location, evaluation, and applicable code.
Compare thermal and ignition barriers - Thermal bridging Building science
-
Also: thermal bridge
Thermal bridging occurs where framing, fasteners, or other conductive paths bypass or weaken insulation. It is one reason cavity R-value is not the same as whole-wall performance.
See how thermal bridges change performance Spray Foam Guides - Two-component foam Materials and application
-
Also: 2K foam, A/B foam
Two-component foam mixes two reactive chemicals during application. Ratio, component temperature, flow, nozzle condition, ventilation, and worker protection affect safety and result quality.
Compare portable two-component systems - Vapor retarder Building science
-
A vapor retarder limits water-vapor diffusion according to measured permeance. It is not the same as an air barrier, and its suitable class and location depend on climate and assembly.
Separate vapor control from air control Spray Foam Guides - Wide-spray foam Materials and application
-
Also: wide spray can
Wide-spray foam uses a fan-shaped or adjustable pattern to cover a small open surface more broadly than a bead. It should be compared with similar cans, not assumed equal to a full insulation kit.
Compare wide-spray products - Yield Performance and quantity
-
Yield is the amount of foam a package produces, often stated in board feet under specified conditions. Advertised theoretical yield can exceed usable field yield after temperature, technique, stops, and waste.
Separate advertised coverage from usable yield